AURORA-H
Continuously Tunable Femtosecond Parametric Amplifier

      Optimal collinear and non-collinear OPA combination

      Ultrafast pulses in the near-infrared spectrum

      Single-shot to 1 MHz repetition rate

      High output stability

      Pulse duration <100 fs

      Tunable spectral bandwidth


The AURORA-H is a hybrid optical parametric amplifier (OPA) that combines the short pulse duration generated by non-collinear OPA (NOPA) with the wide tuning range provided by collinear OPA. This gives it unique performance advantages, allowing its signal light to be tuned in the range of 650-900 nm, while the idler light can be tuned from 1200-2500 nm. Additionally, it can perform dispersion compensation to compress the pulse duration to 50-100 fs.
The AURORA-H is compatible with various market-standard fiber and solid-state Yb ultrafast lasers and supports one-click precise tuning, allowing customers to easily obtain the desired center wavelength output without the need for complex manual adjustments. This not only greatly simplifies the process for customers but also enhances their work efficiency.

Parameter AURORA-H-HP AURORA-H-HE
Tuning range 650 – 900 nm (Signal)
1200 – 2600 nm (Idler)
Maximum pump power 80 W
Maximum pump energy 10-200μJ 200-2000μJ
Peak conversion efficiency > 10% (Signal+Idler)
Second harmonic
Generation (515 nm) conversion
> 35 %
Spectral bandwidth 200 – 750 cm-1 @ 650 – 900 nm
Pulse duration after compressor < 55 fs @ 800 – 900 nm
< 70 fs @ 650 – 800 nm
< 100 fs @ 1200 – 2000 nm
Compressor transmission > 65% @ 650 – 900 nm
> 80% @ 1200 – 2000 nm
Long-term power stability < 1.5% @ 750 nm@ 8h
Pulse-to-pulse energy stability < 1.5% @ 750 nm
Typical pulse duration before
compression
120 - 250 fs
Dimensions (L×W×H) 740x408x222mm (LxWxH)(Compressor not included)
Weight (kg) 75kg(Compressor not included)
Power supply requirements Water-cooled machine:220V/0.6-5.6A/10.2kW(CWUP-10AI)

Product recommendation
AURORA-H Short pulse series

The AURORA-H is a hybrid optical parametric amplifier (OPA) that combines the short pulse duration g...

understand download